AKF-2010V Karl Fischer Moisture Analyzer (for pharmaceutical use)
Market quotation: 36800 RMB
Product details



undefined

undefined

undefined


















Product Name

Type and Model

AKF-2010V Intelligent Karl Fischer Moisture Analyzer

AKF-2010VKarl-Fischer Titrator

Analysis method

Titration method

Volumetric Karl Fischer titration

Volumetric Titration

Titration application

Application

Blank filling (pre titration)

Pre-titration

Reagent calibration

KF Calibration

Karl Fischer titration test

KF titrants

Karl Fischer titration with headspace injection heating

Titration with Heating headspace sampler

Suitable for solid, liquid, and gas samples

Solid, liquid and gaseous samples

Titration control and endpoint

End point of titration

Intelligent titration speed control

Intelligent control titration speed

Automatic standby titration

Standby titration for automatic conditioning

Fully automatic drift endpoint determination (absolute/relative drift, maximum time/volume/)

Drift stop for endpoint recognition (absolute and relative, Tmax, Vmax)

Measurement scope and indicators

Detection range

Content range: 0.001% -100%

Content range:0.001%-100%

Suggested optimal injection volume: consume 0.5ml-4ml Karl Fischer reagent

Recommended injection dose:0.5mL-4mL

Titration accuracy: 1/20000, 1ul (20ml measuring tube), 0.5ul (10ml measuring tube)

Titration accuracy:1/20000,1uL(20mL measuring tube) 0.5uL(10mL measuring tube)

First, prepare a measuring tube: 20ml/10ml/5ml high-precision measuring tube

Measuring tube range: 20mL/10mL/5mL

Measurement results

Results

Automatically calculate and display results (%, ppm, H)2O,mL)

Automatic calculation & result display(%,ppm,H2O,mL)

Result statistics (mean, relative deviation, relative standard deviation)

Record statistics(average value,absolute deviation,RSD)

Titration curve (V-E)

Titration curve(V-E)

Result storage, printing, and output;

Results storage,printing,output

Auxiliary functions

Auxiliary functions

Measuring tube: suction, return, injection, solvent suction, waste liquid discharge, manual stirring

Instrument calibration, waste liquid bottle overflow warning, intelligent fault protection

Imbibition,liquid recovery,liquid injection,solvent inhalation,waste liquid discharge,stirring,device calibration,overflow warning,fault protection

user interface

User interface

Real time display of titration curve on a 7.0-inch large screen;

7.0 "screen display titration curve ;

Can use touch screen input;

LCD touch screen display

GLP/GMP Quality Standards

GLP/GMP conformity

Instrument name and factory number;

Titrator identification and serial number

User unit and operator number;

User unit and operator number;

Instrument calibration function, calibration records;

Checking of burette precision,

User group and user permission settings, as well as user operation records;

User groups and user rights settings, and user operating records

Audit tracking function and audit tracking records;

Audit tracking function and audit trail record;

Experimental report on USB storage prevention;

U disk storage test report;

Valve and pipeline materials

Valves & Piping

PTFE automatic control three-way valve, fully sealed, corrosion-resistant and UV resistant design for the entire pipeline and joints

PTFE electromagnetic valve, corrosion-resistant anti-ultraviolet pipe

Input/output interface

External input/output

Mv/pH measurement electrode interface, reference electrode, PT1000 temperature electrode interface;

RS-232C, USB, Ethernet,Stirring interface

Optional heating mixing station, Karl Fischer headspace sampler, micro data printer

Heated magnetic stirrer(optional),Cassette heating headspace sampler,Micro printer







1. The instrument adopts a fully enclosed titration cell, which can use various Karl Fischer reagents. The system drift is extremely low, and the solvent is automatically replaced and the waste liquid is discharged to avoid the leakage of toxic reagents and the infiltration of environmental moisture; Special nuts and seals are used for pipeline joints.

2. Color LCD touch screen, graphical shortcut key operation is convenient and fast, the test parameter setting method is simple, all analysis results can be stored, and multiple results (moisture content, percentage content, PPM content, Karl Fischer reagent consumption) are displayed simultaneously.

3. The color titration curve is dynamically displayed, and the measurement results are automatically memorized. The measurement results can be output or printed in the format required by GLP/GMP.

4.Carefully designed titration core patented technology, using piston push up buretteWhile significantly reducing the failure rate of the instrument, it also enables the instrument to achieve titration control accuracy. The patented piston head created by Hegong can perfectly match with high-precision measuring tubes in ambient temperatures between -20 ℃ and 40 ℃, and can achieve blowing to push the piston to move without any reagent leakage. It has also created a lifespan that is up to 5 times longer than the other party.

5. The brand new sealing design of the titration cell not only keeps the system extremely low drift, but also prevents toxic reagents from leaking in the cell, ensuring the safety of operators and the environment.Hegong's original patented technology for adding sample portsSuitable for adding samples of different forms such as solids, liquids/gases. Optional micro titration cup and maintenance free dual platinum needle electrode.

6.Password login: Operators log in to the device with their respective usernames and passwords to operateUnauthorized personnel are not allowed to operate and use the system.

7.Permission management: Level 2 management permissions, separating administrators from regular usersOrdinary operators only have operational permissions equivalent to completing their job functions, while administrators have some permissions such as data deletion and data correction.

8.Audit tracking: Method setting, manual operation, parameter modification, and deletion can all fully query relevant records.

9.Result printing: AKF-2010V includes multiple data interfaces: RS-232C connection port, network interface, USB interface;A dedicated needle printer can be optionally selected to print analysis reports at any time. The report data can be exported.

10.3Q certification serviceOptional 3Q authentication service,Fully comply with GMP and FDA related legal and regulatory requirements.

11. Details determine success or failure, and carefully designed casing seals and leak deflectors may never be needed. Because the possibility of liquid leakage has been reduced to one in ten thousand, however, the unwavering design philosophy is to ensure comprehensive protection. The AKF series Karl Fischer moisture analyzer no longer has the common scenario of similar instrument reagents leaking into the instrument host and corroding the internal components of the host.

12. Fully automatic measurement, advanced endpoint algorithm, can use various domestic and foreign brands of Karl Fischer reagents; The measurement is simple, rapid, and accurate; Automatic tracking of environmental moisture drift, which can be automatically deducted to ensure accurate analysis results;

13. The instrument can achieve functions such as inhalation of reagents, measurement, endpoint display, solvent inhalation, waste liquid discharge, stirring, and stepless speed regulation; Instrument status, measurementReal time display of parameters such as pump injection volume, current time, drift, etc.

14. The instrument adjusts the titration speed according to the sample and uses a high-precision titration control system for high detection accuracy; Intelligent fault recognition, automatic shutdown of hardware faults, and protection of important components; The high-precision quantitative tube and anti diffusion titration head using unique patented technology ensure accurate measurement results, stable operation, and extremely low failure rate of the system, and extend the life of key components by more than 5 times.

15. The intelligent reagent management system enables automatic addition of fresh reagents in a fully enclosed state, as well as automatic replacement of Karl Fischer reagents and discharge of waste liquids, effectively protecting experimental personnel from direct contact with toxic solvents and preventing overflow of waste liquid bottles.







undefined








Shanghai Hegong Scientific Instrument Co., Ltd. is an analytical instrument manufacturing enterprise established in 2004 by a group of professional technical personnel who have been engaged in laboratory analytical instrument application and technical services for a long time. The company has an excellent research and development, application, marketing, and technical service team for analytical instruments in China, dedicated to the research and development and production of laboratory analytical instruments. The AKF series Karl Fischer moisture analyzer, gas chromatograph, liquid chromatograph, and sample pretreatment equipment are among the leading analytical instruments in China. The products have been widely used in industrial enterprises such as medicine, food, chemical, petrochemical, metallurgical, energy, biotechnology, aerospace, life sciences, as well as public functional fields such as import and export inspection and quarantine, drug testing, quality inspection, and environmental monitoring. They have also been exported to multiple countries such as India, North Korea, the Middle East, and Southeast Asia, as well as other international markets.














undefined







1.Clear price sales:Each product of Hegong Scientific Instrument is sold at a clear and genuine price, without any hidden operating space such as high price or discount due to moisture content

2.Enjoy a 30 day unconditional return and exchange commitment:Hegong's main products enjoy a 30 day no reason return and exchange policy. For more information, please consult Hegong Scientific Instrument staff.

3.Enjoy 12 months of quality assurance service:What's even more reassuring is that every complete machine product sold by Hegong Scientific Instrument will enjoy high-quality repair costs during the warranty period.

4.12-month extended warranty service:Hegong Scientific Instruments provides extended shelf life services and offers a one-year quality warranty for Hegong products, saving unexpected repair costs.

5.24-hour rapid technical guidance:Whenever and wherever you call the Hegong service hotline, professional engineers will guide you in solving instrument usage skills and product malfunctions.

6.Long term product maintenance and repair services:At any time, Hegong Scientific Instruments provides repair and replacement services for the instruments they produce, regardless of any damage to the appearance, components, or application programs of the instruments.







Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!