9000MNME series online methane/total hydrocarbons/non methane total hydrocarbons analyzer
9000MNME series online methane/total hydrocarbons/non methane total hydrocarbons analyzer
Product details

Product Overview:

9000MNME is used for rapid determination of total hydrocarbons, methane, and non methane total hydrocarbon concentrations in gas samples.

9000MNME utilizes flame ionization detector (FID) and catalytic oxidation device. The total hydrocarbon concentration of the sample is obtained through a FID detector, and the catalytic oxidation device catalyzes the combustion of all hydrocarbons except methane to obtain the methane concentration. The total hydrocarbon value minus the methane value is the non methane total hydrocarbon concentration.

9000MNME can provide fast data analysis with good reproducibility of results.


Technical parameters:

detector FID
oxidation catalytic oxidation


range

The minimum detection limit is 0.02 ppm, 0-50 ppm
The minimum detection limit is 0.06 ppm, 0- 500 ppm
The minimum detection limit is 0.150 ppm, 0-5000 ppm
Detector temperature 65 ℃ (normal temperature type) 120 ℃ (high temperature type)
Catalytic oxidation furnace temperature 230 ℃ (normal temperature type) 215 ℃ (high temperature type)
Repeatability +/- 1%
drift +/- 1% /24h
response time <30 seconds to final reading of 90%
call the police Multi level concentration and fault alarm, sound and light alarm, reflected to external instruments controlled by relays
sampling Built in single point mode, ambient temperature type: with built-in sampling pump or without sampling pump (optional), high temperature type: without sampling pump
calibration Room temperature type: automatic calibration or manual calibration (optional) High temperature type: manual calibration
Supporting gas H2: 35 cc/min. Zero gas 175 cc/min. The hydrocarbon content must be less than 1 ppm
power 90 -230 VAC,50/60 Hz,3A
Relay output 5 programmable forms, relay rated at 3 A @ 230 V AC
Analog output 0-20 mA or 4-20 mA output separately (optional addition of 3 analog output boards)
Digital output RS-232, Ethernet

size
48.26 cm wide x 36.20 cm long x 13.34 cm high weight <9.07 kg
to configure Desktop or 19 inch rack Operating temperature 0 - 40 °C
connect 1/4 inch pipe