Beijing Luda Hengyu Technology Co., Ltd
Home>Products>23819-U, 23829USCOT capillary gas chromatography column
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15810003629
  • Address
    B405, Desheng Kaixuan Building, No. 36 Dewai Street, Xicheng District, Beijing
Contact Now
23819-U, 23829USCOT capillary gas chromatography column
The SCOT Capillary GC Column combines the sensitivity and good sample resolution of capillary gas chromatography, as well as a rich stationary phase l
Product details
Product model23819-U, 23818-U
English nameSCOT Capillary GC Column
scotThe column combines the sensitivity and good sample resolution of capillary gas chromatography, as well as a rich stationary phase library filled with gas chromatography. stayscotIn a capillary column, the inner wall of the capillary is lined with a thin layer of particle carrier, such as diatomaceous earth; Then coat a thin layer of liquid stationary phase on this carrier material. This isscotAnother advantage of the column is that it iswcotThe column has a larger surface area and a thicker fixed phase layer.
Carrier coating open column;
Stainless steel column;
High sensitivity;
Good resolution;
?Multiple fixed phases to choose from;
applicationDepending on the stationary phase, it can be used to separate three isomers of xylene.
 
23819-U
23818-U
23829U
23813-U
material ?
stainless steel
stainless steel
stainless steel
stainless steel
description ?
3.5 in. banded coil
3.5 in. banded coil
3.5 in. banded coil
3.5 in. banded coil
 

BMEA = bis-methoxyethyladipate
TCEP = 1,2,3-tris(2-cyanoethoxy)propane
DNDP = di-n-decyl phthalate
 
Dimensions:? 1/16? in. connections
Dimensions:? 1/16? in. connections
Dimensions:? 1/16? in. connections
Dimensions:? 1/16? in. connections
 
SCOT = Support Coated Open Tubular
SCOT = Support Coated Open Tubular
SCOT = Support Coated Open Tubular
SCOT = Support Coated Open Tubular
Beta value ?
50
40
40
45
application(s) ?
gas chromatography (GC): suitable
gas chromatography (GC): suitable
gas chromatography (GC): suitable
gas chromatography (GC): suitable
L × O.D. ?
50?ft × 1/32? in.
50?ft × 1/32? in.
50?ft × 1/32? in.
50?ft × 1/32? in.
matrix active group ?
Squalane phase
BMEA phase
TCEP phase
Bentone 34/DNDP phase
column type ?
capillary SCOT
capillary SCOT
capillary SCOT
capillary SCOT



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!